RP-HPLC METHOD FOR THE ESTIMATION OF ZILEUTON IN TABLET FORMULATION

Authors

  • Romana Mahivish Department of Pharmaceutical Analysis, Srikrupa Institute of Pharmaceutical Sciences, Siddipet-502 277 (TS), India
  • Manjunath SY Department of Pharmaceutical Analysis, Srikrupa Institute of Pharmaceutical Sciences, Siddipet-502 277 (TS)
  • Hemant Kumar T Head, Department of Pharmaceutical Analysis, Srikrupa Institute of Pharmaceutical Sciences Siddipet-502 277 (TS)

DOI:

https://doi.org/10.29121/granthaalayah.v9.i1.2021.2276

Keywords:

Zileuton, RP-HPLC, Tablet Dosage Form

Abstract [English]

A simple, rapid, accurate and precise RP-HPLC method was developed and validated for the determination of zileuton in table dosage form. Chromatographic analysis of the drug was achieved on Cyberlab HPLC comprising of LC- 100P pump, a variable wavelength programmable LC-UV100 UV detector and SCL system controller.  Flowrosil C18 column (250 mm x 4.6 mm, 5 μ) as stationary phase with mobile phase consisting of Methanol: Acetonitrile: 1% GAA in the ratio of 70:10:20 v/v. The method showed a good linear response in the concentration range of 5-30 μg/ml with correlation coefficient of 0.9993. The flow rate was maintained at 1.0 ml/min and detection was carried out at 230 nm. The retention time was 3.12 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, solution stability, selectivity and sensitivity. The results obtained in the study were within the limits of ICH guidelines and hence this method can be used for the determination of zileuton in tablet formulation.

Downloads

Download data is not yet available.

References

Rask-Madson J, Buckhave K, Laursen LS, Lauritsen K.5-Lipoxygenase inhibitors for the treatment of inflammatory bowel disease. Agents and Actions.1992; 36:37-46. DOI: https://doi.org/10.1007/BF01991022

Zouboulis CC. Zileuton, a new efficient and safe systemic anti-acne drug. Dermato-Endocrinology. 2009; 1:188-192. DOI: https://doi.org/10.4161/derm.1.3.8368

Kumar AK, Nareshbabu N. Development and Validation of Analytical method for the Estimation of Zileuton in Bulk and in Pharmaceutical dosage forms by UV Spectroscopy. International Research Journal of Pharmacy. 2012; 3:154-157.

Romana Mahivish, Manjunath SY and Hemant Kumar. UV spectrophotometric method for estimation of zileuton in pharmaceutical formulation. GSC Biological and Pharmaceutical Sciences, 2020, 13(01), 212-219. DOI: https://doi.org/10.30574/gscbps.2020.13.1.0338

Ganorkar SB, Shirkhedkar AA, Dhumal DM. Application of UV-spectrophotometry for determination of zileuton in bulk and in tablets. Indian Drugs, 2013; 50: 40-43.

Vara KPR, Tanuja M, Rao YS, Kumar HT. Development and Validation of Stability Indicating UV Spectrophotometric Method for The Estimation of Zileuton In Bulk and Tablet Dosage Form. International Journal of Pharmacy, 2015; 5(2) :393-397.

Kumar HT, Rao KVP, Tanuja, Rao YS. Validated visible spectrophotometric methods for determination of Zileuton in pharmaceutical formulation. International Journal of Pharmacy. 2015; 6: 397-405.

Rao KVP, Tanuja, Rao YS, Kumar HT. Development and Validation of Spectrophotometric Methods for Estimation of Zileuton In Bulk and Its Dosage Form. International Journal of Chemical Sciences. 2015; 13(2): 714-724.

Ganorkar SB, Shirkhedkar AA. Novel HPTLC and UV-AUC analyses: For simple, economical, and rapid determination of Zileuton racemate. Arabian Journal of Chemistry. 2017; 10: 360–367. DOI: https://doi.org/10.1016/j.arabjc.2013.05.013

Rao KVP, Tanuja M, Rao YS, Kumar TH. Visible spectrophotometric methods for determination of zileuton in bulk drug and pharmaceutical formulation. International Journal of Research in Pharmacy and Chemistry. 2015; 5(2) :251–257.

Shirkhedkar AA, Ganorkar SB, Dhumal DM (2017) Development and validation of simple RP-HPLC-PDA analytical protocol for zileuton assisted with Design of Experiments for robustness determination. Arabian Journal of Chemistry. 2017; 10: 273-282.

Rao KVP, Tanuja M, Rao YS, Kumar TH. Development and Validation of RP-HPLC method for the estimation of Zileuton in bulk and its dosage form. International Journal of Drug Development & Research. 2015; 7(1) :101-106.

Granneman GR, Braeckman RA, Erdman KA. Determination of a new 5-lipoxygenase inhibitor, zileuton, and its inactive N-dehydroxylated metabolite in plasma by high performance liquid chromatography. Clinical Pharmacokinetics, 1995; 29: 1-8. DOI: https://doi.org/10.2165/00003088-199500292-00003

Prakash K, Adiki SK, Kalakuntla RR (2014) Development and validation of a liquid chromatography mass spectrometry method for the determination of zileuton in human plasma. Scientia Pharmaceutica. 2014; 82:571–583.

Pian P, Labovitz E, Hoffman K, Clavijo CF, Lynn RR, Galinkin JL, Vinks AA, Malik P, Christians U. Quantification of the 5-lipoxygenase inhibitor zileuton in human plasma using high performance liquid chromatography–tandem mass spectrometry. Journal of Chromatography B. 2013; 937:79–83. DOI: https://doi.org/10.1016/j.jchromb.2013.08.014

Bhavana V, Hemant TK, Srinivasa YR, Rao KVP. RP-HPLC method for estimation of Solifenacin Succinate in API and Tablet dosage form.Asian Journal of Pharmaceutical Analysis.9(3); 2019:118-122. DOI: https://doi.org/10.5958/2231-5675.2019.00022.X

Mounika PS, Hemant TK, Srinivasa YR, Rao KVP. RP-HPLC Method for Quantification of Empagliflozin In Pharmaceutical Formulation. Asian Journal of Pharmacy and Technology.9(3); 2019:208-211. DOI: https://doi.org/10.5958/2231-5713.2019.00035.7

ICH - Guidelines Q2A, Validation of Analytical Procedures: Definition and Terminology (CPMP III/5626/94) March (1995). Geneva, Switzerland: ICH. ICH - Guidelines Q2B, Validation of Analytical Procedures: Methodology, (CPMP/ICH/281/95) November (1996). Geneva, Switzerland: ICH.

Downloads

Published

2021-01-31

How to Cite

Mahivish, R., SY, M., & Kumar, H. (2021). RP-HPLC METHOD FOR THE ESTIMATION OF ZILEUTON IN TABLET FORMULATION. International Journal of Research -GRANTHAALAYAH, 9(1), 141–149. https://doi.org/10.29121/granthaalayah.v9.i1.2021.2276