COMPARISON BETWEEN RECTAL AND BODY SURFACE TEMPERATURES OBTAINED BY DIGITAL AND NON-CONTACT INFRARED THERMOMETER IN SOME LARGE ANIMAL SPECIES

Authors

  • Mera Usman Muhammed Department of Veterinary Medicine, Faculty of Veterinary Medicine, Usmanu Danfodiyo University, Sokoto, Nigeria
  • Mayaki Abubakar Musa Department of Veterinary Medicine, Faculty of Veterinary Medicine, Usmanu Danfodiyo University, Sokoto, Nigeria
  • Gambo Abdulrahman Abdullahi Department of Veterinary Medicine, Faculty of Veterinary Medicine, Usmanu Danfodiyo University, Sokoto, Nigeria

DOI:

https://doi.org/10.29121/granthaalayah.v7.i8.2019.639

Keywords:

Digital Rectal Thermometer, Non-Contact Infrared Thermometer, Large Animal Species

Abstract [English]

This study was carried out to compare the digital rectal (DR) thermometer with non-contact infrared thermometer (IRT) measurements at two locations on the face in some large animal species. Two hundred and forty (240) animals comprising of equal numbers of three species (cattle, camel and horses) of varying age and either sex was used. The IR temperature was taken from two sites [frontal (FIRT) and temporal (TIRT) region] on the animal face. The mean IR temperatures (FIRT and TIRT) were higher than the RT in all the animal species. The two thermometers correlate poorly in all the animal species. Bland-Altman analysis showed high biases and limits of agreement not acceptable for clinical purposes. In conclusion, IRT seems to offer a quick and easy way to determine the animal temperature but clinically it cannot be used interchangeably with DR thermometer at the moment for body temperature measurement in these animal species.

Downloads

Download data is not yet available.

References

Berry, R.J., Kennedy, A.D., Scott, S.L., Kyle, B.L. and Schaefer, A.L. (2003). Daily variation in the udder surface temperature of dairy cows measured by infrared thermography: Potential for mastitis detection. Can. J. Anim. Sci. 83, 687–693. DOI: https://doi.org/10.4141/A03-012

Bland, J.M. and Altman, DG. (1986). Statistical methods for assessing agreement between 2 methods of clinical measurement. Lancet 1:307–310.

Brunell, M.K. (2012). Comparison of noncontact infrared thermometry and 3 commercial subcutaneous temperature transponding microchips with rectal thermometry in rhesusmacaques (Macaca mulatta). J Am Assoc Lab Anim Sci. 51(4):479–484.

Chung, T-h., Jung, W-s., Nam, E-h., Kim, J-h., Park, S-h and Hwang, C-Y. (2010). Comparison of rectal and infrared thermometry for obtaining body temperature of gnotobiotic piglets in conventional portable germ free facility. Asian-Aust. J. Anim. Sci. 23(10):1364-1368.

Devalle. (2005) Comparison of tympanic, transponder, and noncontact infrared laser thermometry with rectal thermometry in strain 13 guinea pigs. Contemp Topics Lab Anim Sci. 44(5):35–38.

Drew, M.L. (1996). The use of a tympanic membrane thermometer for assessing hyperthermia in bighorn sheep. J Wildl Dis. 32(3):512–516.

Fraden, J. and Lackey, R.P. (1991). Estimation of body sites temperatures from tympanic measurements. Clin Pediatr. 30(4):65-70.

Fortuna, E.L, Carney, M.M, Macy, M, et al. (2010). Accuracy of non-contact infrared thermometry versus rectal thermometry in young children evaluated in the emergency department for fever. J Emerg Nurs. 36(2):101–104.

Goodwin, S. (1998). Comparison of body temperatures of goats, horses, and sheep measured with a tympanic infrared thermometer, an implantable microchip transponder, and a rectal thermometer. Contemp. Top. Lab. Anim. Sci. 37(3):51-55.

Johnson, S.R., Rao, S., Hussey, S.B., Morley, P.S., Traub-Dargatz, J.L. (2011). Thermographic eye temperature as an index to body temperature in ponies. J Equine Vet Sci. 31:63–6.

Kunkle, G.A., Nicklin, C.F. and Sullivan-Tamboe, D.L. (2004). Comparison of body temperature in cats using a veterinary infrared thermometer and a digital rectal thermometer. J. Am Anim Hosp Assoc. 40(1):42-46.

Monthanoli, Y.R., Swanson, K.C., Palme, R., Schenkel, F.S., McBride, B.W., Lu, D. and Miller, S.P. (2010). Assessing efficiency in beef steers through feeding behaviour, infrared thermography and glucocorticoids. Animal, 4(5):692-701.

Nobel, J.J. (1992) Infrared ear thermometry. Pediatr Emerg Care. 8(1):54-58. DOI: https://doi.org/10.1097/00006565-199202000-00016

Osio, C.E. and Carnelli, V. (2007). Comparative study of body temperature measured with a non-contact infrared thermometer versus conventional devices. Minerva Pediatr. 59:327-36.

Patel, A.H., Patel, M.M. and Bhavsar, R.H. (2016). Comparison of Non-Contact Forehead Infrared Thermometry with Axillary Digital Thermometry in Neonates. GCSMC J. Med. Sci. 20(1): 20-24

Quimby, J.M., Olea-Popelka, F. and Lappin, M.R. (2009). Comparison of Digital Rectal and Microchip Transponder Thermometry in Cats. Journal of the American Association for Laboratory Animal Science. 48(4): 1-4

Rainwater-Lovett, K., Pacheco, J.M., Packer, C. and Rodriguez, L.L. (2009). Detection of foot-and mouth disease virus infected cattle using infrared thermography. The Veterinary Journal, 180:317–324.

Ramey, D., Bachmann, K. and Lee, M.L. (2011). A comparative study of noncontact infrared and digital rectal thermometer measurements of body temperature in the horse. J Eq Vet Sci 31(4):191–193.

Rubia-Rubia, J., Arias, A., Sierra, A, Aguirre-Jaime, A. (2011). Measurement of body temperature in adult patients: Comparative study of accuracy, reliability and validity of different devices. International Journal of Nursing Studies. 48:872–880.

Schmidt, M., Lahrmann, K-H., Ammon, C., Berg, W., Schön, P. and Hoffmann, G. (2013). Assessment of body temperature in sows by two infrared thermography methods at various body surface locations. J Swine Health Prod. 21:203–9.

Shelton, Jr L.J., White, C.E. and Felt, S.A. (2006). A comparison of non-contact, subcutaneous, and rectal temperatures in captive owl monkeys (Aotus sp.). J Med Primatol. 35(6):346-51.

Sikoski, P., Banks, M., Gould, R., et al. (2007). Comparison of rectal and infrared thermometry for obtaining body temperature in cynomolgus macaques (Macaca fascicularis). J Med Primatol. 36(6):381–384.

Southward, E., Mann, F.A, Dodam, J., et al. (2006). A comparison of auricular, rectal and pulmonary artery thermometry in dogs with anesthesia induced hypothermia. J Vet Emerg Crit Care. 16(3):172–175.

Sousa, M.G., Carareto, R., Pereira-Junior, V., et al. (2011)Comparison between auricular and standard rectal thermometers for the measurement of body temperature in dogs. Can J Vet Res. 52(4):403-406.

Sousa, M.G., Carareto, R., Pereira-Junior, V.A., et al. (2013). Agreement between auricular and rectal measurements of body temperature in healthy cats. J Fel Med Surg. 15(4):275–279.

Teran, C.G., Torrez-Llanos, J., Teran-Miranda, T.E., et al. (2012). Clinical accuracy of a non-contact infrared skin thermometer in paediatric practice. Child Care Health Dev. 38(4):471–476.

Wiedemann, G.G.S., Saclon, M.C., Paludo, G., Silva, I.O., Boere, V. (2006). Comparison between tympanic and anal temperature with a clinical infrared ray thermometer in dogs. Arq. Bras. Med. Vet. Zootec. 58: 503-505.

Downloads

Published

2019-08-31

How to Cite

Muhammed, M. U., Musa, M. A., & Abdullahi, G. A. (2019). COMPARISON BETWEEN RECTAL AND BODY SURFACE TEMPERATURES OBTAINED BY DIGITAL AND NON-CONTACT INFRARED THERMOMETER IN SOME LARGE ANIMAL SPECIES. International Journal of Research -GRANTHAALAYAH, 7(8), 62–68. https://doi.org/10.29121/granthaalayah.v7.i8.2019.639