PERFORMANCE OF A TANGENTIALLY FIRED BOILER IN A THERMAL POWER PLANT

Authors

  • Koilada Abhinash M.Tech., Student, Department of Mechanical Engineering, College of Engineering (A), Andhra University, Visakhapatnam, Andhra Pradesh, India
  • P.S. Kishore Ph.D., Professor, Department of Mechanical Engineering, College of Engineering (A), Andhra University, Visakhapatnam, Andhra Pradesh, India

DOI:

https://doi.org/10.29121/granthaalayah.v6.i5.2018.1467

Keywords:

Tangential Burner, Heat Supplier, Heat Losses, Work Input, Work Output and Efficiency

Abstract [English]

The most effective method for producing intense turbulence is by the impingement of one flame on another.  This action is secured through the use of burners located in each of the four corners of the furnace.  The burner nozzles are so directed that the streams of coal and air are projected along a line tangent to a small circle, lying in a horizontal plane, at the centre of the furnace.  A scrubbing action is present which assures contact between the combustible and oxygen, thus promoting rapid combustion and reducing carbon loss.  The experimental results of this study can be summarized as the use of tangentially fired boiler which increase splendid air-fuel mixture and pulverized coal is entrained in Primary Air (PA), and in-addition to that the Secondary Air (SA) is also projected towards the mill, finally a rotating “FIRE BALL” is formed.


The present work analysis is carried out on Tangentially Fired Boiler by considering heat input through four burners.  The heat output is determined by considering various losses from the boiler that is loss due to dry gas, loss due to moisture, loss due to H2 for combustion, heat loss due to combustile and refuse and losses due to radiation etc.  In addition heat absorbed by economizer, boilers, superheater and reheater are studied, thus finally the net heat absorbed and thermal efficiency of tangentially fired boiler are determined.


Graphs are drawn to evaluate the various effects of heat input on output parameters in the boiler.  Sankey diagrams are drawn to show the performance in the boiler.  The values calculated are put and shown as tables in Appendix.

Downloads

Download data is not yet available.

References

G.R. Offen, J.P.Kesserburg, K. Lee G. Poe., control of particulate matter from Tangential fired burners, Environmental protection agency, Reduction of Co2 Emissions, North Carolina, pp.7-1 to 7-27, 2015

Mr.Ashish Fande and P.V.Joshi, Practical boiler operation in the Power Plant, Applied Science and Engineering, 4th Edition, PHI Learning Private Limited, Part-IV, PP-101-126, 2015.

Cristians V.da Silva, Study the analysis of tangentially fired burners, Reduction of Co2 emissions controlled by the burners, consolidated Edison Company of New York, Vol.4; No.5 PP 157-261, 2004.

B.F.Piper, KVB, in C., New York State Energy Research and Development Authority, Combustion of Bituminous Coal in Pulverized State and liquids in tangential fired boiler, Vol.43, No.16, pp.1012-10 22, 2000.

Infante Ferreira, Carlos.A, Applied thermal Engineering, Utility of tangential boilers, their Design construction and Management, New Age publishers, Vol.IV.

V. Vara Lakshmi and P.S. Kishore, “Thermal Efficiency of Pulverized Fuel Boiler”, publisehd in Internatinoal Advanced Research Journal in Sciencey, Engineering & Technology, Vol.2, No.1 PP.45-49, Jan., 2015. DOI: https://doi.org/10.17148/IARJSET.2015.2107

Haiying Qi, Bo Zhao, Ken Gregory, Experimental investigation on gas flow in a model of tangentially fired boiler, A Options for limiting Carbondioxide Vol.18, pp. 14-17, 2006.

Su Cheng-dong, Tang Xu, W.T. Reid, Research on emission characteristics on axial compression, Internal deposits of Tangential boilders, 38(AO I):12-18, pp.44-52, 2013.

M. Praveen, P.S. Kishore, “Effectiveness of Rotary Air Preheater in a Thermal Power Plant”, International Journal of Scientific Engineering and Technology, Vol.5, No.12, PP. 526-531, Dec. 2016.

Y.K. Rao, P. Chattopadhyay, Stoichiometri and Thermodynamic processes, Operation in tangentially fired boiler, M.C.Graw Hill Education, Pvt. Limited, 3rd, Edition, pp.119-127, 2013.

C.S.Rao, Environmental pollution and control Engineering, New Age international publishers, 2nd Edition, pp.137-156, 2007.

Louis Jestin, Cenkefa, Prabir Basu, Boilers and burners, its Design and theory, Mechanical Engineering Series, Spring Publishers, 1st Edition, Vol.III, pp.112-122, 2001.

R.K.Rajput, Thermal Engineering, 8th Edition, Lakshmi Publications Pvt. Ltd. pp.592-608, 2010.

Thomos shakre, Mahallawy. Conventional fossil fuel Power Plant during combustion process in tangentially firing system, International Journal Engineering, Vol.3, pp.101-116, Feb. 2015.

Robert E. Hall, Saven Andersson, Khatri, Emissions and performance of boilers in the combustion process, International Journal, Engineering Issue 4, Volume 9, pp. 551-563, 2010.

K. Abhinash, performance of a Tangentially Fired Boiler in a thermal power plant, M.Tech Thesis, Andhra University, 2018.

Downloads

Published

2018-05-31

How to Cite

Abhinash, K., & Kishore, P. (2018). PERFORMANCE OF A TANGENTIALLY FIRED BOILER IN A THERMAL POWER PLANT. International Journal of Research -GRANTHAALAYAH, 6(5), 391–406. https://doi.org/10.29121/granthaalayah.v6.i5.2018.1467