ENERGY DETECTION IN THE FORM OF LIGHT RADIATION AT END OF HUMAN BLOOD COAGULATION CASCADE- THE OPTICAL ABSORPTION OF WATER VS. FIBRIN BURST ENERGY RELEASE

Authors

  • Abraham A. Embi Bs MBA 13442 SW 102 Lane, Miami, Florida USA, 33186

DOI:

https://doi.org/10.29121/granthaalayah.v7.i9.2019.602

Keywords:

In Vivo Blood Smears, TBIS, Blood Coagulation Cascade, Piezoelectric Effect, Metal Iron Conductivity, Graphite Conductivity, Fibrin Burst Light Radiation, Optical Absorption of Water

Abstract [English]

The human blood coagulation cascade had been extensively researched from a biochemistry and molecular perspective. The purpose of this manuscript is to introduce a biophysical phenomenon detected via optical microscopy at the end of the human blood coagulation cascade. This could be described as a sudden energy event in the form of light radiation observed once blood tissue movement stops being attracted to metal iron filings or carbon based graphite particles used as sentinels. Upon close examination of video recordings, the sudden movements of iron particles images coincided with light at the end of the coagulation cascade. A literature search confirmed that both metal filings and graphite particles to possess excellent electrical conductivity. A biophysical light radiation event discharge is hypothesized as result of a burst in the conversion of fibrinogen to fibrin signaling the end of a coagulation cycle; perhaps combined with a piezoelectric effect induced by a sudden clumping of RBCs, or from the optical absorption or water.


Method: Metal iron filings or graphite particles were randomly sprinkled on fresh TIBS preparations. The sample was then readily focused and selected particles chosen for video analysis. Equipment used was a video microscope Celestron Model # 44348, glass slides and author’s blood drops. The data was digitally transferred and stored in an Apple computer photo application for further review.


Results: When metal iron filings or graphite particles were sprinkled on freshly prepared TIBS slides, video analysis show light radiation emitted at the end of the blood coagulation cascade.


Discussion: Since the light radiation emission occurred at the end of the blood coagulation cycle, it is theorized that blood tissue compression could induce piezoelectricity coinciding with energy released by a fibrin burst, or by the optical absorption of water.

Downloads

Download data is not yet available.

References

Embi AA. “BIOMAGNETISM AS FACTOR IN RED BLOOD CELLS DEFORMATION.” International Journal of Research - Granthaalayah, 2018 6 (12), 46-57.

https://doi.org/10.5281/zenodo.2528404.

Embi AA. Hair and blood endogenous low level biomagnetic fields cross-talk effects on fibrin inhibition and rouleau formation. IJGR, 2018 6(11), 200-208. https://doi.org/10.5281/zenodo. 1845985.

Embi AA. Expanding the role of magnetic fields in red blood cells deformations: Demonstration of paramagnetic and diamagnetic fields. IJRG, 2019 7(2), 214-220.

https://doi.org/10.5281/zenodo.2587463

Wolberg, A. S., & Campbell, R. A. Thrombin generation, fibrin clot formation and hemostasis. Transfusion and apheresis science: official journal of the World Apheresis Association: official journal of the European Society for Haemapheresis, 2008 38(1), 15–23. doi:10.1016/j.transci.2007.12.005 DOI: https://doi.org/10.1016/j.transci.2007.12.005

Smith, S. A., Travers, R. J., & Morrissey, J. H. How it all starts: Initiation of the clotting cascade. Critical reviews in biochemistry and molecular biology, 2015 50(4), 326–336. doi:10.3109/10409238.2015.1050550 DOI: https://doi.org/10.3109/10409238.2015.1050550

Bates S.M. Coagulation Assays. Circulation; 112:e53–e60. doi: 10.1161/CIRCULATION AHA. 2005 104.478222

Sperling C., Fischer M., Maitz M.F., Werner C. Blood coagulation on biomaterials requires the combination of distinct activation processes. Biomaterials. 2009; 30: 4447–4456. doi: 10.1016/j.biomaterials.2009.05.044 DOI: https://doi.org/10.1016/j.biomaterials.2009.05.044

Weisel, J.W., & Litvinov, R.I. Mechanisms of fibrin polymerization and clinical implications. Blood, 2013 121 10, 1712-9 DOI: https://doi.org/10.1182/blood-2012-09-306639

Center for Disease Control. USA. Suggested technique for BloodSmear.

https://www.cdc.gov/dpdx/diagnosticprocedures/blood/specimenproc.html

Ragheb, T., & Geddes, L.A. Electrical properties of metallic electrodes. Medical and Biological Engineering and Computing, 1990 28, 182-186. DOI: https://doi.org/10.1007/BF02441775

Liu, N., Chortos, A., Lei, T., Jin, L., Kim, T.R., Bae, W., Zhu, C., Wang, S., Pfattner, R., Chen, X., Sinclair, R., & Bao, Z. Ultratransparent and stretchable graphene electrodes. Sci Adv. 2017 Sep 8;3 (9):e1700159. doi: 10.1126/sciadv.1700159. DOI: https://doi.org/10.1126/sciadv.1700159

Embi AA. The Dual Effect on Eukaryotic Cells of Bursting Air Bubbles Shockwaves Induced Piezoelectric Effect as Additional Factor in Extracorporeal Focused Very Intense Pressure Pulse Cancer Cells Treatments. Acta Scientific Cancer Biology 2019 3. 10 : 24-28.

C. K. N. Patel and A. C. Tam, “Optical absorption coefficients of water,” 1979 Nature London 280, 302–304. DOI: https://doi.org/10.1038/280302a0

Downloads

Published

2019-09-30

How to Cite

Embi Bs, A. A. (2019). ENERGY DETECTION IN THE FORM OF LIGHT RADIATION AT END OF HUMAN BLOOD COAGULATION CASCADE- THE OPTICAL ABSORPTION OF WATER VS. FIBRIN BURST ENERGY RELEASE. International Journal of Research -GRANTHAALAYAH, 7(9), 200–212. https://doi.org/10.29121/granthaalayah.v7.i9.2019.602