FILM REJECT ANALYSIS AS A MEASURE OF QUALITY ASSURRANCE: A CASE STUDY OF SOME SELECTED HOSPITALS IN PLATEAU STATE, NIGERIA

Authors

DOI:

https://doi.org/10.29121/granthaalayah.v9.i10.2021.4288

Keywords:

X-Ray, Rejected Films, Quality Assurance, Over Exposure, Under Exposure

Abstract [English]

Film reject analysis is a planned and systematic action necessary to provide adequate confidence that a product or service will satisfy the given requirement for quality of image or radiographs. In this research work, reject film analysis as quality assurance element will be carried out in 3 selected hospitals in Plateau state, Nigeria for different rejected film sizes in each case respectively from December, 2018- December, 2019. Rejected radiographs were collected analyzed and categorized based on body parts such as chest, skull, knee, lumbar sacral, shoulder, neck, femur and pelvis. The reasons for rejection were categorized as: Over exposure, Under exposure, Poor processing, Poor positioning, Wrong placing of anatomical marker, Fog, Artifact and Multiple exposure. The three studied hospitals (selected by convenience), H1, H2, and H3 are located in Jos and environs. From this study, it was observed that the anatomical part mostly rejected was the chest and the highest reason for the rejected radiographs was Under exposure. The reject rates of Hospitals H1, H2, and H3 were found to be 8.85%, 6.65% and 5.6% respectively which were above the World Health Organization(WHO) but within the Conference of Radiation Control Program Directorate (CRCPD) recommended permissible values of 5% and (5-10%) respectively. The findings imply that patients may have been exposed to avoidable radiation doses

Downloads

Download data is not yet available.

References

Banahene J. O., Darko E.O., Hersferd F., Addison E. K. &Asiriji J. O (2017); Film Reject Analysis and Image Quality in Diagnostic Radiology Department of a Teaching Hospital in Ghana. Journal of Radiation Research and Applied Sciences.(7): 589-594. Retrieved from https://doi.org/10.1016/j.jrras.2014.09.012 DOI: https://doi.org/10.1016/j.jrras.2014.09.012

Charlene B., Christine D., Edwin R. D., Mondijala A., & Caroline N. (2018); The cause of reject images in radiology department at a state hospital in Windhoek, Namibia. The south African Radiographer 56(1); 35-39. Retrieved from https://journals.co.za/doi/pdf/10.10520/EJC-ed5d71aed

Dunn, M. A, & Rogers, A. T. (1998); X-ray film reject analysis as quality indicator. Radiography, 29-31. Retrieved from https://doi.org/10.1016/S1078-8174(98)80027-8 DOI: https://doi.org/10.1016/S1078-8174(98)80027-8

Joseph D. Z., Mohammad S., Abubakar M., Goni M., & Otopa R (2015); Film reject analysis in radiology department of a teaching hospital in Northern-eastern. Nigeria. Nigeria Journal of Medial Imaging and Radiation Therapy.4(1);21-27

Jwanbot D.I, Sirisena U.A.I, Akpolile F.D,Tangtur T.S & Nkop P.M (2017); Analysis of reject radiographic films as quality assurance element in diagnostic radiology. International Journal of Innovative Healthcare Research 5(1);24-30

Nwobi I.C., Agwu K. K.,Garba I. & James P (2011); Analysis of Rejected Films At The University of Maiduguri Teaching Hospital (UMTH). Nigerian Journal Of Medical Imaging And Radiation Therapy.1(2): 23-26.

Teferi S., Zawdeneh D., Admassie D., Nigatu B. & Kebeta K (2010); X-ray Film Reject Rate Analysis at Eight Selected Government Hospitals in Addis Ababa, Ethiopia. Ethiopia J. Health Development. 26(1): 54-59. Retrieved from https://www.ajol.info/index.php/ejhd/article/view/83829

Watkinson, S., Moores, B. M., & Hill, S. J. (1984). Reject analysis: its role in quality assurance. Radiography, 50(593), 189-194. Retrieved from https://europepmc.org/article/med/6484122

Downloads

Published

2021-10-31

How to Cite

Mangset, W., Sauri, K., & Langs, D. (2021). FILM REJECT ANALYSIS AS A MEASURE OF QUALITY ASSURRANCE: A CASE STUDY OF SOME SELECTED HOSPITALS IN PLATEAU STATE, NIGERIA. International Journal of Research -GRANTHAALAYAH, 9(10), 88–93. https://doi.org/10.29121/granthaalayah.v9.i10.2021.4288